Experimental Determination Features of Acousto-Optical Figure of Merit for Crystalline Materials
D.M. Vynnyk, A.T. Ratych, M.I. Kyryk, I.V. Yidak, A.S. Andrushchak
Lviv Polytechnic National University, Bandera Str. 12, 79013 Lviv, Ukraine
Full Text PDF
The paper specifies the Dixon-Cohen method for the experimental determination of the acousto-optical figure of merit M2. In particular, the conditions are formulated when the Dixon-Cohen method application for M2 determination is possible without significant errors. Cases are considered when the condition of the ``weak field'' in the studied material is not satisfied, as well as when the transmission of the studied and reference materials is less than 100%. The error in determining the acousto-optical figure of merit M2 in the case of unenlightened test material, using CaWO4 and GaP crystals as an example, is estimated, and the limits of application of the ``weak field'' approximation in these two crystals are established.

DOI:10.12693/APhysPolA.141.396
topics: figure of merit, Dixon-Cohen method, Bragg diffraction