Analytical Investigation on Some K X-Ray Fluorescence Parameters of Barium Compounds
B. Göker Durdua, E. Akkutlub, A. Küçükönderc, d, H. Çame
aKilis 7 Aralik University, Vacational School of Health Services, Opticianry Program, Karataş Campus, 79000, Kilis-Turkey
bKilis 7 Aralik University, The Institute for Graduate Studies in Science and Engineering, Department of Physics, Karataş Campus, 79000, Kilis-Turkey
cKahramanmaras Sütcü Imam University, Faculty of Science and Letters, Department of Physics, Avşar Campus, 46100, K. Maraş-Turkey
dKahramanmaraş Istiklal University Rectorate, Cumhuriyet Street 7, 46100, K. Maraş-Turkey
eKahramanmaras Sütcü Imam University, Vacational School of Technical Sciences, Electronic Technology Program, Avşar Campus, 46100, K. Maraş-Turkey
Full Text PDF
Fluorescence cross-sections (σ, σ, σtotal), Kβ/Kα X-ray intensity ratios, probabilities of the vacancy transfer from K to L shell (ηKL), and Auger electrons emission ratios for Ba compounds were studied using Ki (i=α,β) X-rays line intensities. The samples were excited by γ-rays 59.5 keV produced by the 241Am radioisotope source. The K X-rays emitted from the samples were detected with a high resolution Si(Li) detector. The experimental results were compared with other theoretical and experimental values of Ba compounds.

DOI:10.12693/APhysPolA.141.474