Effects of Core Dimensions and Manufacturing Procedure on Fluxgate Noise |
M. Janošeka, J. Vyhnáneka, A. Zikmunda, P. Butvinb, B. Butvinováb
aDept. of Measurement, FEE, Czech Technical University in Prague, Technická 2, 166 27 Praha, Czech Republic bInstitute of Physics, Slovak Academy of Sciences, Dúbravská cesta 9, 84511 Bratislava, Slovakia |
Full Text PDF |
The effect of demagnetizing factor and manufacturing procedure on noise of the fluxgate probes, manufactured from metallic glasses, is presented. The fluxgate probes were either tape-wound, or flat, wet-etched ringcore and race-track geometries. When combining low demagnetizing factor and high enough cross-section of the probe, a minimum in the noise dependence can be found. For 50 mm ringcores, in such minimum the noise value as low as 7 pTRMS in 0.1-10 Hz frequency band was achieved, which is very low for an as-cast tape, and has not been reported before. |
DOI: 10.12693/APhysPolA.126.104 PACS numbers: 75.75.-c, 75.30.-m, 75.50.-y, 07.55.-w, 75.70.-i |