The Critical Evaluation of the Vibroacoustic Criteria Used in Poland to Diagnose of Power Transformer Cores |
S. Borucki, A. Cichon, T. Boczar and D. Zmarzly
Faculty of Electrical Engineering, Automatic Control and Computer Science, Opole University of Technology, Prószkowska 76, 45-758 Opole, Poland |
Full Text PDF |
The subject matter of this article concerns the diagnostic test results of transformer cores by measuring and analysing vibroacoustic signals registered during their normal operation. The main objective of this research study conducted by the authors, the results of which are published in this paper, is a critical analysis of vibroacoustic criteria, which are adopted in Poland nowadays, and based on which, the assessment of the core technical condition is performed. This article presents exemplary results that were obtained on two twin units of type TET 8509 with a power of 40 MVA. The paper specifies diagnosed structures, the measurement system applied, and the currently used methodology to assess the degree of core loosening. To determine the efficacy and assessment accuracy of the applied vibroacoustic criteria, correlation between mechanical vibration measurements of the tested transformer tanks and results obtained by gas chromatography was performed. |
DOI: 10.12693/APhysPolA.124.391 PACS numbers: 43.40.-r, 43.40.Vn, 43.58.Wc |