Three-Quantum Annihilation in Porous Vycor Glass
B. Jasińska, J. Wawryszczuk and R. Zaleski
Institute of Physics, Maria Curie-Skłodowska University, pl. Marii Curie-Skłodowskiej 1, 20-031 Lublin, Poland
Full Text PDF
Received: 20 09 2004;
Three methods of determination of 3γ o-Ps decay intensity are compared. The estimate of 3γ fraction obtained from classical lifetime measurements can be distorted due to a higher absorption of theγ quanta from the continuous spectrum of three-quantum decay, compared to two-quantum one.
DOI: 10.12693/APhysPolA.107.821
PACS numbers:36.10.Dr, 78.70.Bj